1 protected starter
защищенный пускатель
Комбинация пускателя, коммутационного аппарата с ручным управлением и аппарата защиты от коротких замыканий в оболочке или без нее, смонтированных и соединенных по инструкции изготовителя.
Примечание. Коммутационный аппарат с ручным управлением и аппарат защиты от коротких замыканий могут представлять собой единый аппарат и оснащаться дополнительно защитой от перегрузок.
[ ГОСТ Р 50030.4.1-2002 (МЭК 60947-4-1-2000)]EN
protected starter
equipment consisting of a starter, a manually-operated switching device and a short-circuit protective device, rated as a unit by the manufacturer
NOTE 1 - The protected starter may or may not be enclosed.
NOTE 2 - In the context of this standard, the term “manufacturer“ means any person, company or organization with ultimate responsibility as follows:
– to verify compliance with the appropriate standard;
– to provide the product information according to Clause 6.
NOTE 3 - The manually operated switching device and the short-circuit protective device may be just one device and may also incorporate the starter overload protection.
[IEC 60947-4-1, ed. 3.0 (2009-09)]FR
démarreur protégé
matériel comprenant un démarreur, un appareil de connexion à commande manuelle et un dispositif de protection contre les courts-circuits, caractérisé comme une unité par le fabricant
NOTE 1 - Le démarreur protégé peut ou non être sous enveloppe.
NOTE 2 - Dans le contexte de la présente norme, le terme «fabricant» signifie toute personne, entreprise ou organisation ayant la responsabilité ultime:
– de vérifier la conformité avec la norme appropriée;
– de fournir l’information sur le matériel selon l’Article 6.
NOTE 3 - L'appareil de connexion à commande manuelle et le dispositif de protection contre les courts-circuits peuvent être seulement un appareil et peuvent également incorporer la protection contre les surcharges du démarreur.
[IEC 60947-4-1, ed. 3.0 (2009-09)]Тематики
- аппарат, изделие, устройство...
- контакторы и пускатели
EN
FR
комбинированный пускатель
Комбинация пускателя, коммутационного аппарата с наружным органом ручного управления и аппарата защиты от коротких замыканий, смонтированных и соединенных в предусмотренной для этого оболочке. Функции коммутационного аппарата и аппарата защиты от коротких замыканий могут выполнять комбинация с плавкими предохранителями, выключатель с плавкими предохранителями или автоматический выключатель, пригодный или непригодный для разъединения.
1 — автоматический выключатель; 2 — контактор; 3 — реле перегрузки; 4 — выключатель цепи управления; 5 — автоматический выключатель с одним только магнитным расцепителем; 6 — выключатель-разъединитель; 7 — плавкий предохранитель; 8 — разъединитель с плавким предохранителем; 9— автоматический выключатель с расцепителем перегрузки, соответствующим настоящему стандарту
1 Предусмотренная оболочка — это специально спроектированная и рассчитанная для данного применения оболочка, в которой проводят все испытания.
2 Коммутационный аппарат с ручным управлением и устройство защиты от коротких замыканий могут представлять собой единый аппарат и оснащаться дополнительно защитой от перегрузок.
[ ГОСТ Р 50030.4.1-2002 (МЭК 60947-4-1-2000)]EN
protected starter
equipment consisting of a starter, a manually-operated switching device and a short-circuit protective device, rated as a unit by the manufacturer
NOTE 1 The protected starter may or may not be enclosed.
NOTE 2 In the context of this standard, the term “manufacturer“ means any person, company or organization with ultimate responsibility as follows:
– to verify compliance with the appropriate standard;
– to provide the product information according to Clause 6.
NOTE 3 The manually operated switching device and the short-circuit protective device may be just one device and may also incorporate the starter overload protection.
[IEC 60947-4-1, ed. 3.0 (2009-09)]
combination starter
equipment consisting of a protected starter incorporating an isolating function
NOTE Also called "combination motor controller".
[IEC 60947-4-1, ed. 3.0 (2009-09)]FR
démarreur protégé
matériel comprenant un démarreur, un appareil de connexion à commande manuelle et un dispositif de protection contre les courts-circuits, caractérisé comme une unité par le fabricant
NOTE 1 Le démarreur protégé peut ou non être sous enveloppe.
NOTE 2 Dans le contexte de la présente norme, le terme «fabricant» signifie toute personne, entreprise ou organisation ayant la responsabilité ultime:
– de vérifier la conformité avec la norme appropriée;
– de fournir l’information sur le matériel selon l’Article 6.
NOTE 3 L'appareil de connexion à commande manuelle et le dispositif de protection contre les courts-circuits peuvent être seulement un appareil et peuvent également incorporer la protection contre les surcharges du démarreur.
[IEC 60947-4-1, ed. 3.0 (2009-09)]
combiné de démarrage
matériel comprenant un démarreur protégé incorporant une fonction de sectionnement
NOTE Également appelé «combiné contrôleur de moteur».
[IEC 60947-4-1, ed. 3.0 (2009-09)]Параллельные тексты EN-RU
Combination starter
Equipment consisting of a starter and a short-circuit protective device, mounted and wired in a dedicated enclosure. The switching and short-circuit protective devices may be a fuse combination unit, a switch with fuses or a circuit-breaker with or without an isolating function.
[ABB]Комбинированный пускатель
Комбинация пускателя и аппарата защиты от коротких замыканий, смонтированных и соединенных в предусмотренной для этого оболочке. Функции коммутационного аппарата и аппарата защиты от коротких замыканий могут выполнять комбинация с плавкими предохранителями, выключатель с плавкими предохранителями или автоматический выключатель, пригодный или непригодный для разъединения.
[Перевод Интент]Тематики
EN
FR
Англо-русский словарь нормативно-технической терминологии > protected starter
-
2 combination starter
комбинированный пускатель
Комбинация пускателя, коммутационного аппарата с наружным органом ручного управления и аппарата защиты от коротких замыканий, смонтированных и соединенных в предусмотренной для этого оболочке. Функции коммутационного аппарата и аппарата защиты от коротких замыканий могут выполнять комбинация с плавкими предохранителями, выключатель с плавкими предохранителями или автоматический выключатель, пригодный или непригодный для разъединения.
1 — автоматический выключатель; 2 — контактор; 3 — реле перегрузки; 4 — выключатель цепи управления; 5 — автоматический выключатель с одним только магнитным расцепителем; 6 — выключатель-разъединитель; 7 — плавкий предохранитель; 8 — разъединитель с плавким предохранителем; 9— автоматический выключатель с расцепителем перегрузки, соответствующим настоящему стандарту
1 Предусмотренная оболочка — это специально спроектированная и рассчитанная для данного применения оболочка, в которой проводят все испытания.
2 Коммутационный аппарат с ручным управлением и устройство защиты от коротких замыканий могут представлять собой единый аппарат и оснащаться дополнительно защитой от перегрузок.
[ ГОСТ Р 50030.4.1-2002 (МЭК 60947-4-1-2000)]EN
protected starter
equipment consisting of a starter, a manually-operated switching device and a short-circuit protective device, rated as a unit by the manufacturer
NOTE 1 The protected starter may or may not be enclosed.
NOTE 2 In the context of this standard, the term “manufacturer“ means any person, company or organization with ultimate responsibility as follows:
– to verify compliance with the appropriate standard;
– to provide the product information according to Clause 6.
NOTE 3 The manually operated switching device and the short-circuit protective device may be just one device and may also incorporate the starter overload protection.
[IEC 60947-4-1, ed. 3.0 (2009-09)]
combination starter
equipment consisting of a protected starter incorporating an isolating function
NOTE Also called "combination motor controller".
[IEC 60947-4-1, ed. 3.0 (2009-09)]FR
démarreur protégé
matériel comprenant un démarreur, un appareil de connexion à commande manuelle et un dispositif de protection contre les courts-circuits, caractérisé comme une unité par le fabricant
NOTE 1 Le démarreur protégé peut ou non être sous enveloppe.
NOTE 2 Dans le contexte de la présente norme, le terme «fabricant» signifie toute personne, entreprise ou organisation ayant la responsabilité ultime:
– de vérifier la conformité avec la norme appropriée;
– de fournir l’information sur le matériel selon l’Article 6.
NOTE 3 L'appareil de connexion à commande manuelle et le dispositif de protection contre les courts-circuits peuvent être seulement un appareil et peuvent également incorporer la protection contre les surcharges du démarreur.
[IEC 60947-4-1, ed. 3.0 (2009-09)]
combiné de démarrage
matériel comprenant un démarreur protégé incorporant une fonction de sectionnement
NOTE Également appelé «combiné contrôleur de moteur».
[IEC 60947-4-1, ed. 3.0 (2009-09)]Параллельные тексты EN-RU
Combination starter
Equipment consisting of a starter and a short-circuit protective device, mounted and wired in a dedicated enclosure. The switching and short-circuit protective devices may be a fuse combination unit, a switch with fuses or a circuit-breaker with or without an isolating function.
[ABB]Комбинированный пускатель
Комбинация пускателя и аппарата защиты от коротких замыканий, смонтированных и соединенных в предусмотренной для этого оболочке. Функции коммутационного аппарата и аппарата защиты от коротких замыканий могут выполнять комбинация с плавкими предохранителями, выключатель с плавкими предохранителями или автоматический выключатель, пригодный или непригодный для разъединения.
[Перевод Интент]Тематики
EN
FR
Англо-русский словарь нормативно-технической терминологии > combination starter
-
3 self-starter
[ˌself'stɑːtə]1) Общая лексика: самопуск, инициативность (as personal quality listed in CV, job advert etc)2) Разговорное выражение: инициативный человек3) Военный термин: (автоматический) стартёр4) Техника: автоматический пускатель, автоматический стартёр5) Железнодорожный термин: автоматический пуск6) Автомобильный термин: автоматический (напр. электрический) стартёр7) Психология: вечный двигатель, то, что приводит себя в действие8) Реклама: зачинатель, инициатор -
4 alarm signalling device
извещатель тревожной сигнализации
Ручной или автоматический прибор в системе охранной или пожарной сигнализации
[Терминологический словарь по строительству на 12 языках (ВНИИИС Госстроя СССР)]EN
DE
FR
Англо-русский словарь нормативно-технической терминологии > alarm signalling device
-
5 thirty-eight
Большой англо-русский и русско-английский словарь > thirty-eight
-
6 thirtyeight
thirty-eight
1> револьвер или автоматический пистолет калибром 3,8
миллиметра -
7 self-starter
механический ( или автоматический) пускательАнгло-русский словарь нефтегазовой промышленности > self-starter
-
8 autoclear
-
9 manual or automatic
Техника: ручной или автоматический -
10 reaction cavity
-
11 thirty-eight
[ˌθɜːtɪ'eɪt] -
12 M/A
manual or automatic - ручной или автоматический -
13 autoclear
автоматическое переключение или автоматический переключатель с засекреченной на открытую связьАнгло-русский словарь по компьютерной безопасности > autoclear
-
14 thirty-eight
-
15 watchdog
раза устройство обеспечения безопасности (напр. плавкий предохранитель или автоматический выключатель) -
16 thirty-eight
n револьвер или автоматический пистолет калибром 3,8 миллиметра -
17 auto-cutout
автоматический выключатель
Механический коммутационный аппарат1), способный включать, проводить и отключать токи при нормальном состоянии электрической цепи, а также включать, проводить в течение заданного времени и автоматически отключать токи в указанном аномальном состоянии электрической цепи, например, при коротком замыкании.
(МЭС 441-14-20)
[ ГОСТ Р 50030. 2-99 ( МЭК 60947-2-98)]
автоматический выключатель
-
[IEV number 442-05-01]EN
circuit breaker
a mechanical switching device, capable of making, carrying and breaking currents under normal circuit conditions and also making, carrying for a specified time and breaking currents under specified abnormal circuit conditions such as those of short circuit.
[IEC 62271-100, ed. 2.0 (2008-04)]
[IEV number 442-05-01]
circuit breaker
A device designed to open and close a circuit by nonautomatic means and to open the circuit automatically on a predetermined overcurrent without damage to itself when properly applied within its rating.
NOTE The automatic opening means can be integral, direct acting with the circuit breaker, or remote from the circuit breaker.
Adjustable (as applied to circuit breakers). A qualifying term indicating that the circuit breaker can be set to trip at various values of current, time, or both within a predetermined range. Instantaneous-trip (as applied to circuit breakers). A qualifying term indicating that no delay is purposely introduced in the tripping action of the circuit breaker.
Inverse-time (as applied to circuit breakers). A qualifying term indicating a delay is purposely introduced in the tripping action of the circuit breaker, which delay decreases as the magnitude of the current increases.
Nonadjustable (as applied to circuit breakers). A qualifying term indicating that the circuit breaker does not have any adjustment to alter the value of current at which it will trip or the time required for its operation.
Setting (of a circuit breaker). The value of current, time, or both at which an adjustable circuit breaker is set to trip.
[National Electrical Cod]FR
disjoncteur
1) Должно быть контактный коммутационный аппарат
appareil mécanique de connexion capable d’établir, de supporter et d’interrompre des courants dans les conditions normales du circuit, ainsi que d’établir, de supporter pendant une durée spécifiée et d’in- terrompre des courants dans des conditions anormales spécifiées du circuit telles que celles du court-circuit.
[IEC 62271-100, ed. 2.0 (2008-04)]
[IEV number 442-05-01]
[Интент]КЛАССИФИКАЦИЯ
- По роду тока
- По напряжению
- По числу полюсов
- По виду корпуса
- По месту установки
- По изолирующей среде
- По установленным расцепителям
- По дополнительным защитам
- По назначению
- По категории применения
- По виду привода взвода пружины
- По выполняемой функции
-
По влиянию монтажного положения
Автоматические выключатели ABB Модульные автоматические выключатели
1. НЕКОТОРЫЕ СВЕДЕНИЯ ОБ АВТОМАТИЧЕСКИХ ВЫКЛЮЧАТЕЛЯХ Автоматический выключатель — это электрический аппарат, который автоматически отключает (и тем самым защищает) электрическую цепь при возникновении в ней аномального режима. Режим становится аномальным, когда в цепи начинает недопустимо изменяться (т. е. увеличиваться или уменьшаться относительно номинального значения) ток или напряжение.
Другими словами (более "инженерно") можно сказать, что автоматический выключатель защищает от токов короткого замыкания и токов перегрузки отходящую от него питающую линию, например, кабель и приемник(и) электрической энергии (осветительную сеть, розетки, электродвигатель и т. п.).
Как правило, автоматический выключатель может применятся также для нечастого (несколько раз в сутки) включения и отключения защищаемых электроприемников (защищаемой нагрузки).
[Интент]Выключатель предназначен для проведения тока в нормальном режиме и отключения тока при коротких замыканиях, перегрузках, недопустимых снижениях напряжения, а также до 30 оперативных включений и отключений электрических цепей в сутки и рассчитан для эксплуатации в электроустановках с номинальным рабочим напряжением до 660 В переменного тока частоты 50 и 60 Гц и до 440 В постоянного тока.
[Типовая фраза из российской технической документации] 2. ПРИНЦИП ДЕЙСТВИЯ Для защиты цепи от короткого замыкания применяется автоматический выключатель с электромагнитным расцепителем.1 - Пружина (в данном случае во взведенном положении растянута)
Автоматический выключатель устроен таким образом, что сначала необходимо взвести пружину и только после этого его можно включить. У многих автоматических выключателей для взвода пружины необходимо перевести ручку вниз. После этого ручку переводят вверх. При этом замыкаются главные контакты.
2 - Главный контакт автоматического выключателя
3 - Удерживающее устройство
4 - Электромагнитный расцепитель;
5 - Сердечник
6 - Катушка
7 - Контактные зажимы автоматического выключателя
На рисунке показан один полюс автоматического выключателя во включенном положении: пружина 1 взведена, а главный контакт 2 замкнут.
Как только в защищаемой цепи возникнет короткое замыкание, ток, протекающий через соответствующий полюс автоматического выключателя, многократно возрастет. В катушке 6 сразу же возникнет сильное магнитное поле. Сердечник 5 втянется в катушку и освободит удерживающее устройство. Под действием пружины 1 главный контакт 2 разомкнется, в результате чего автоматический выключатель отключит и тем самым защитит цепь, в которой возникло короткое замыкание. Такое срабатывание автоматического выключателя происходит практически мгновенно (за сотые доли секунды).
Для защиты цепи от тока перегрузки применяют автоматические выключатели с тепловым расцепителем.1 - Пружина (в данном случае во взведенном положении растянута)
Принцип действия такой же как и в первом случае, с той лишь разницей, что удерживающее устройство 3 освобождается под действием биметаллической пластины 5, которая изгибается от тепла, выделяемого нагревательным элементом 6. Количество тепла определяется током, протекающим через защищаемую цепь.
2 - Главный контакт автоматического выключателя
3 - Удерживающее устройство
4 - Тепловой расцепитель
5 - Биметаллическая пластина
6 - Нагревательный элемент
7 - Контактные зажимы автоматического выключателя
[Интент]Недопустимые, нерекомендуемые
Тематики
Классификация
>>>Обобщающие термины
Действия
- включение автоматического выключателя
- оперирование автоматического выключателя
- отключение автоматического выключателя
- срабатывание автоматического выключателя
EN
- auto-cutout
- automatic circuit breaker
- automatic cutout
- automatic switch
- breaker
- CB
- circuit breaker
- circuit-breaker
- cutout
DE
FR
Смотри также
Англо-русский словарь нормативно-технической терминологии > auto-cutout
18 automatic circuit breaker
автоматический выключатель
Механический коммутационный аппарат1), способный включать, проводить и отключать токи при нормальном состоянии электрической цепи, а также включать, проводить в течение заданного времени и автоматически отключать токи в указанном аномальном состоянии электрической цепи, например, при коротком замыкании.
(МЭС 441-14-20)
[ ГОСТ Р 50030. 2-99 ( МЭК 60947-2-98)]
автоматический выключатель
-
[IEV number 442-05-01]EN
circuit breaker
a mechanical switching device, capable of making, carrying and breaking currents under normal circuit conditions and also making, carrying for a specified time and breaking currents under specified abnormal circuit conditions such as those of short circuit.
[IEC 62271-100, ed. 2.0 (2008-04)]
[IEV number 442-05-01]
circuit breaker
A device designed to open and close a circuit by nonautomatic means and to open the circuit automatically on a predetermined overcurrent without damage to itself when properly applied within its rating.
NOTE The automatic opening means can be integral, direct acting with the circuit breaker, or remote from the circuit breaker.
Adjustable (as applied to circuit breakers). A qualifying term indicating that the circuit breaker can be set to trip at various values of current, time, or both within a predetermined range. Instantaneous-trip (as applied to circuit breakers). A qualifying term indicating that no delay is purposely introduced in the tripping action of the circuit breaker.
Inverse-time (as applied to circuit breakers). A qualifying term indicating a delay is purposely introduced in the tripping action of the circuit breaker, which delay decreases as the magnitude of the current increases.
Nonadjustable (as applied to circuit breakers). A qualifying term indicating that the circuit breaker does not have any adjustment to alter the value of current at which it will trip or the time required for its operation.
Setting (of a circuit breaker). The value of current, time, or both at which an adjustable circuit breaker is set to trip.
[National Electrical Cod]FR
disjoncteur
1) Должно быть контактный коммутационный аппарат
appareil mécanique de connexion capable d’établir, de supporter et d’interrompre des courants dans les conditions normales du circuit, ainsi que d’établir, de supporter pendant une durée spécifiée et d’in- terrompre des courants dans des conditions anormales spécifiées du circuit telles que celles du court-circuit.
[IEC 62271-100, ed. 2.0 (2008-04)]
[IEV number 442-05-01]
[Интент]КЛАССИФИКАЦИЯ
- По роду тока
- По напряжению
- По числу полюсов
- По виду корпуса
- По месту установки
- По изолирующей среде
- По установленным расцепителям
- По дополнительным защитам
- По назначению
- По категории применения
- По виду привода взвода пружины
- По выполняемой функции
-
По влиянию монтажного положения
Автоматические выключатели ABB Модульные автоматические выключатели
1. НЕКОТОРЫЕ СВЕДЕНИЯ ОБ АВТОМАТИЧЕСКИХ ВЫКЛЮЧАТЕЛЯХ Автоматический выключатель — это электрический аппарат, который автоматически отключает (и тем самым защищает) электрическую цепь при возникновении в ней аномального режима. Режим становится аномальным, когда в цепи начинает недопустимо изменяться (т. е. увеличиваться или уменьшаться относительно номинального значения) ток или напряжение.
Другими словами (более "инженерно") можно сказать, что автоматический выключатель защищает от токов короткого замыкания и токов перегрузки отходящую от него питающую линию, например, кабель и приемник(и) электрической энергии (осветительную сеть, розетки, электродвигатель и т. п.).
Как правило, автоматический выключатель может применятся также для нечастого (несколько раз в сутки) включения и отключения защищаемых электроприемников (защищаемой нагрузки).
[Интент]Выключатель предназначен для проведения тока в нормальном режиме и отключения тока при коротких замыканиях, перегрузках, недопустимых снижениях напряжения, а также до 30 оперативных включений и отключений электрических цепей в сутки и рассчитан для эксплуатации в электроустановках с номинальным рабочим напряжением до 660 В переменного тока частоты 50 и 60 Гц и до 440 В постоянного тока.
[Типовая фраза из российской технической документации] 2. ПРИНЦИП ДЕЙСТВИЯ Для защиты цепи от короткого замыкания применяется автоматический выключатель с электромагнитным расцепителем.1 - Пружина (в данном случае во взведенном положении растянута)
Автоматический выключатель устроен таким образом, что сначала необходимо взвести пружину и только после этого его можно включить. У многих автоматических выключателей для взвода пружины необходимо перевести ручку вниз. После этого ручку переводят вверх. При этом замыкаются главные контакты.
2 - Главный контакт автоматического выключателя
3 - Удерживающее устройство
4 - Электромагнитный расцепитель;
5 - Сердечник
6 - Катушка
7 - Контактные зажимы автоматического выключателя
На рисунке показан один полюс автоматического выключателя во включенном положении: пружина 1 взведена, а главный контакт 2 замкнут.
Как только в защищаемой цепи возникнет короткое замыкание, ток, протекающий через соответствующий полюс автоматического выключателя, многократно возрастет. В катушке 6 сразу же возникнет сильное магнитное поле. Сердечник 5 втянется в катушку и освободит удерживающее устройство. Под действием пружины 1 главный контакт 2 разомкнется, в результате чего автоматический выключатель отключит и тем самым защитит цепь, в которой возникло короткое замыкание. Такое срабатывание автоматического выключателя происходит практически мгновенно (за сотые доли секунды).
Для защиты цепи от тока перегрузки применяют автоматические выключатели с тепловым расцепителем.1 - Пружина (в данном случае во взведенном положении растянута)
Принцип действия такой же как и в первом случае, с той лишь разницей, что удерживающее устройство 3 освобождается под действием биметаллической пластины 5, которая изгибается от тепла, выделяемого нагревательным элементом 6. Количество тепла определяется током, протекающим через защищаемую цепь.
2 - Главный контакт автоматического выключателя
3 - Удерживающее устройство
4 - Тепловой расцепитель
5 - Биметаллическая пластина
6 - Нагревательный элемент
7 - Контактные зажимы автоматического выключателя
[Интент]Недопустимые, нерекомендуемые
Тематики
Классификация
>>>Обобщающие термины
Действия
- включение автоматического выключателя
- оперирование автоматического выключателя
- отключение автоматического выключателя
- срабатывание автоматического выключателя
EN
- auto-cutout
- automatic circuit breaker
- automatic cutout
- automatic switch
- breaker
- CB
- circuit breaker
- circuit-breaker
- cutout
DE
FR
Смотри также
Англо-русский словарь нормативно-технической терминологии > automatic circuit breaker
19 automatic cutout
автоматический выключатель
Механический коммутационный аппарат1), способный включать, проводить и отключать токи при нормальном состоянии электрической цепи, а также включать, проводить в течение заданного времени и автоматически отключать токи в указанном аномальном состоянии электрической цепи, например, при коротком замыкании.
(МЭС 441-14-20)
[ ГОСТ Р 50030. 2-99 ( МЭК 60947-2-98)]
автоматический выключатель
-
[IEV number 442-05-01]EN
circuit breaker
a mechanical switching device, capable of making, carrying and breaking currents under normal circuit conditions and also making, carrying for a specified time and breaking currents under specified abnormal circuit conditions such as those of short circuit.
[IEC 62271-100, ed. 2.0 (2008-04)]
[IEV number 442-05-01]
circuit breaker
A device designed to open and close a circuit by nonautomatic means and to open the circuit automatically on a predetermined overcurrent without damage to itself when properly applied within its rating.
NOTE The automatic opening means can be integral, direct acting with the circuit breaker, or remote from the circuit breaker.
Adjustable (as applied to circuit breakers). A qualifying term indicating that the circuit breaker can be set to trip at various values of current, time, or both within a predetermined range. Instantaneous-trip (as applied to circuit breakers). A qualifying term indicating that no delay is purposely introduced in the tripping action of the circuit breaker.
Inverse-time (as applied to circuit breakers). A qualifying term indicating a delay is purposely introduced in the tripping action of the circuit breaker, which delay decreases as the magnitude of the current increases.
Nonadjustable (as applied to circuit breakers). A qualifying term indicating that the circuit breaker does not have any adjustment to alter the value of current at which it will trip or the time required for its operation.
Setting (of a circuit breaker). The value of current, time, or both at which an adjustable circuit breaker is set to trip.
[National Electrical Cod]FR
disjoncteur
1) Должно быть контактный коммутационный аппарат
appareil mécanique de connexion capable d’établir, de supporter et d’interrompre des courants dans les conditions normales du circuit, ainsi que d’établir, de supporter pendant une durée spécifiée et d’in- terrompre des courants dans des conditions anormales spécifiées du circuit telles que celles du court-circuit.
[IEC 62271-100, ed. 2.0 (2008-04)]
[IEV number 442-05-01]
[Интент]КЛАССИФИКАЦИЯ
- По роду тока
- По напряжению
- По числу полюсов
- По виду корпуса
- По месту установки
- По изолирующей среде
- По установленным расцепителям
- По дополнительным защитам
- По назначению
- По категории применения
- По виду привода взвода пружины
- По выполняемой функции
-
По влиянию монтажного положения
Автоматические выключатели ABB Модульные автоматические выключатели
1. НЕКОТОРЫЕ СВЕДЕНИЯ ОБ АВТОМАТИЧЕСКИХ ВЫКЛЮЧАТЕЛЯХ Автоматический выключатель — это электрический аппарат, который автоматически отключает (и тем самым защищает) электрическую цепь при возникновении в ней аномального режима. Режим становится аномальным, когда в цепи начинает недопустимо изменяться (т. е. увеличиваться или уменьшаться относительно номинального значения) ток или напряжение.
Другими словами (более "инженерно") можно сказать, что автоматический выключатель защищает от токов короткого замыкания и токов перегрузки отходящую от него питающую линию, например, кабель и приемник(и) электрической энергии (осветительную сеть, розетки, электродвигатель и т. п.).
Как правило, автоматический выключатель может применятся также для нечастого (несколько раз в сутки) включения и отключения защищаемых электроприемников (защищаемой нагрузки).
[Интент]Выключатель предназначен для проведения тока в нормальном режиме и отключения тока при коротких замыканиях, перегрузках, недопустимых снижениях напряжения, а также до 30 оперативных включений и отключений электрических цепей в сутки и рассчитан для эксплуатации в электроустановках с номинальным рабочим напряжением до 660 В переменного тока частоты 50 и 60 Гц и до 440 В постоянного тока.
[Типовая фраза из российской технической документации] 2. ПРИНЦИП ДЕЙСТВИЯ Для защиты цепи от короткого замыкания применяется автоматический выключатель с электромагнитным расцепителем.1 - Пружина (в данном случае во взведенном положении растянута)
Автоматический выключатель устроен таким образом, что сначала необходимо взвести пружину и только после этого его можно включить. У многих автоматических выключателей для взвода пружины необходимо перевести ручку вниз. После этого ручку переводят вверх. При этом замыкаются главные контакты.
2 - Главный контакт автоматического выключателя
3 - Удерживающее устройство
4 - Электромагнитный расцепитель;
5 - Сердечник
6 - Катушка
7 - Контактные зажимы автоматического выключателя
На рисунке показан один полюс автоматического выключателя во включенном положении: пружина 1 взведена, а главный контакт 2 замкнут.
Как только в защищаемой цепи возникнет короткое замыкание, ток, протекающий через соответствующий полюс автоматического выключателя, многократно возрастет. В катушке 6 сразу же возникнет сильное магнитное поле. Сердечник 5 втянется в катушку и освободит удерживающее устройство. Под действием пружины 1 главный контакт 2 разомкнется, в результате чего автоматический выключатель отключит и тем самым защитит цепь, в которой возникло короткое замыкание. Такое срабатывание автоматического выключателя происходит практически мгновенно (за сотые доли секунды).
Для защиты цепи от тока перегрузки применяют автоматические выключатели с тепловым расцепителем.1 - Пружина (в данном случае во взведенном положении растянута)
Принцип действия такой же как и в первом случае, с той лишь разницей, что удерживающее устройство 3 освобождается под действием биметаллической пластины 5, которая изгибается от тепла, выделяемого нагревательным элементом 6. Количество тепла определяется током, протекающим через защищаемую цепь.
2 - Главный контакт автоматического выключателя
3 - Удерживающее устройство
4 - Тепловой расцепитель
5 - Биметаллическая пластина
6 - Нагревательный элемент
7 - Контактные зажимы автоматического выключателя
[Интент]Недопустимые, нерекомендуемые
Тематики
Классификация
>>>Обобщающие термины
Действия
- включение автоматического выключателя
- оперирование автоматического выключателя
- отключение автоматического выключателя
- срабатывание автоматического выключателя
EN
- auto-cutout
- automatic circuit breaker
- automatic cutout
- automatic switch
- breaker
- CB
- circuit breaker
- circuit-breaker
- cutout
DE
FR
Смотри также
Англо-русский словарь нормативно-технической терминологии > automatic cutout
20 plug-in circuit breaker
автоматический выключатель втычного исполнения
Выключатель, который дополнительно к своим отключающим контактам имеет комплект контактов, позволяющих снимать выключатель.
Примечание
Некоторые выключатели могут быть втычными только со стороны питания, зажимы со стороны нагрузки обычно пригодны для присоединения проводников.
[ ГОСТ 50030.2-99]
автоматический выключатель втычного типа
Выключатель с одним или несколькими штыревыми выводами, использующийся с соответствующим устройством для штепсельного соединения.
[ ГОСТ Р 50345-99( МЭК 60898-95)]
Автоматический выключатель со штыревыми выводами, предназначенными для выполнения разъемного соединения с основанием автоматического выключателя, к выводам которого подключаются проводники внешних электрических цепей.
Такие аппараты вставляются и извлекаются без обесточивания соответствующей цепи. Присоединение и отсоединение аппарата возможно только в том случае, если аппарат разомкнут.
В противном случае при отсоединении происходит автоматическое размыкание контактов аппарата.
В простых ситуациях съемные аппараты можно использовать для реализации функции разъединения.
Обычно втычные аппараты применяют в тех случаях, когда необходимо обеспечить легкую замену аппаратов, что делает их обслуживание очень удобным.
Аппараты съемного исполнения иногда обозначаются буквой D (disconnectable – отсоединяемое исполнение).EN
plug-in circuit-breaker
a circuit-breaker which, in addition to its interrupting contacts, has a set of contacts which enable the circuit-breaker to be removed
NOTE Some circuit-breakers may be of the plug-in type on the line side only, the load terminals being usually suitable for wiring connection.
[< size="2">IEC 60947-2, ed. 4.0 (2006-05)]FR
disjoncteur enfichable
disjoncteur qui, outre ses contacts d’interruption, possède un jeu de contacts permettant le retrait du disjoncteur
NOTE Certains disjoncteurs peuvent être de type enfichable sur le côté d’alimentation uniquement, les bornes de sortie étant les bornes utilisées habituellement pour raccordement par conducteurs.
[< size="2">IEC 60947-2, ed. 4.0 (2006-05)]Основание автоматического выключателя втычного исполнения
Рис. LegrandАвтоматический выключатель втычного (съемного исполнения), смонтированный на основании с выводами для заднего присоединения проводников
Рис. Legrand1 - Монтажная панель
2 - Выводы для переднего присоединения проводников
3 - Основание с выводами для переднего присоединения проводников ( front terminal plug-in base)
4 - Автоматический выключатель втычного исполнения1 - Монтажная панель
2 - Выводы для заднего присоединения проводников
3 - Основание с выводами для заднего присоединения проводников ( rear terminal plug-in base)
4 - Автоматический выключатель втычного исполненияPlug-in devices
Plug-in device makes it possible to extract and/or rapidly replace the circuit breaker without having to touch connections for ship and important installations.
Автоматические выключатели втычного исполнения
Конструкция втычных автоматических выключателей обеспечивает их быструю замену, т. е. позволяет снимать и возвращать их на свое место, без отсоединения проводников, что очень важно в корабельных и ответственных электроустановках.The plug-in base is the fixed part of the plug-in version of the circuit-breaker. It will be installed directly on the back plate of panel.
Основание является неподвижной частью втычного выключателя. Оно крепится непосредственно к монтажной панели.
The circuit-breaker is racked out by unscrewing the top and bottom fixing screws.
[LS Industrial Systems]Прежде чем извлечь автоматический выключатель из основания, необходимо выкрутить верхний и нижний крепежные винты.
[Перевод Интент]Тематики
Классификация
>>>Синонимы
- автоматический выключатель съемного исполнения
- втычной автоматический выключатель
- съемный автоматический выключатль
EN
FR
Англо-русский словарь нормативно-технической терминологии > plug-in circuit breaker
См. также в других словарях:
Автоматический комплект (альбом) — Автоматический комплект Студийный альбом Юрия Чернавского … Википедия
Автоматический режим косвенного управления при выполнении функции АСУТП — Режим выполнения функции АСУТП, при котором комплекс средств автоматизации АСУТП автоматически изменяет установки и (или) параметры настройки систем локальной автоматики технологического объекта управления. Источник … Словарь-справочник терминов нормативно-технической документации
Автоматический пистолет — Steyr M1912 … Википедия
автоматический выключатель — Механический коммутационный аппарат1), способный включать, проводить и отключать токи при нормальном состоянии электрической цепи, а также включать, проводить в течение заданного времени и автоматически отключать токи в указанном аномальном… … Справочник технического переводчика
автоматический выключатель — Механический коммутационный аппарат1), способный включать, проводить и отключать токи при нормальном состоянии электрической цепи, а также включать, проводить в течение заданного времени и автоматически отключать токи в указанном аномальном… … Справочник технического переводчика
Автоматический пистолет Стечкина — АПС Тип: Автоматический пистолет Страна … Википедия
Автоматический дробовик — дробовик (ружьё), имеющий или допускающий возможность стрельбы в автоматическом режиме. Автоматический дробовик по своему внутреннему и конструктивному устройству напоминает автомат или автоматическую винтовку. Боевые характеристики… … Википедия
Автоматический режим прямого (непосредственного) цифрового (или аналого-цифрового) управления при выполнении управляющей функции АСУ ТП — Режим выполнения функции АСУТП, при котором комплекс средств автоматизации АСУ ТП вырабатывает и реализует управляющие воздействия непосредственно на исполнительные механизмы технологического объекта управления. Источник … Словарь-справочник терминов нормативно-технической документации
автоматический выключатель втычного исполнения — Выключатель, который дополнительно к своим отключающим контактам имеет комплект контактов, позволяющих снимать выключатель. Примечание Некоторые выключатели могут быть втычными только со стороны питания, зажимы со стороны нагрузки обычно пригодны … Справочник технического переводчика
автоматический выключатель втычного исполнения — Выключатель, который дополнительно к своим отключающим контактам имеет комплект контактов, позволяющих снимать выключатель. Примечание Некоторые выключатели могут быть втычными только со стороны питания, зажимы со стороны нагрузки обычно пригодны … Справочник технического переводчика
Автоматический режим косвенного управления при выполнении функции АСУ ТП — Режим выполнения функции АСУ ТП, при котором комплекс средств автоматизации АСУ ТП автоматически изменяет установки и (или) параметры настройки систем локальной автоматики технологического объекта управления. Источник … Словарь-справочник терминов нормативно-технической документации
Перевод: с английского на русский
с русского на английский- С русского на:
- Английский
- С английского на:
- Русский